Active
UNERASER

User's Guide for Windows

How to erase hard drive? Windows7 logo   How to erase hard drive? Intel logo

Re-create Deleted or Damaged Disk Array (RAID) Virtually

There are many reasons for a Redundant Array of Independent Disks (RAID) system to fail (RAID controller failures, software RAID emulator errors, etc.). Active@ UNERASER provides an easy way to assemble array disks together and make damaged or deleted data accessible.

You can combine together a disk that was previously used as a part of a RAID system in a temporal (virtual) disk array. With this virtual configuration, you are able to perform all drive file recovery manipulations as though it is regular drive. You can even to create a Disk Image for the whole RAID and store it to the safe location.

It is important that you specify the parameters of the RAID system that you know existed before the fault so that you can virtually reassemble the same system.

It is also important to list the disks in the correct order when making a virtual disk array. In most cases, the correct order is unknown. The only way to discover the correct order is to try all available combinations until you reach the one that works. If you are dealing with only two disks, it is simple. You have only two ways to arrange the order. If there are three disks, you must try a maximum of six combinations. If there are four disks, 24 combinations, and so on...

Each time you try a combination, write down the order you are trying, click OK and check the results by trying to access and scan the newly-created virtual RAID that is added to the list of Local System Devices. If you don't see your data or if there was an error during virtual array creation, mark this one as a failure and try another order of disks in array.

To create a Virtual Disk Array (RAID):

  1. To open Recreate Disk Array (RAID) dialog, in the Action menu, choose Recreate RAID (Virtually)... UNERASER software: Recreate Disk Array (RAID) dialog
  2. To choose a supported RAID type, in the Virtual Volume Type area, choose one of the following:
    • Stripe Array (RAID-0) — Data located in stripes (blocks of size 32KB, 64KB, 128KB, etc.) distributed between two or more drives
    • Mirror Array (RAID-1) — Data on two disks is identical - provides complete data duplication (or mirroring)
    • RAID-5 Array — Data located in stripes distributed between two or more drives with parity control
    • Span Array — Data located contiguously on one disk then on another disk, and so on...
  3. To select disks from a list to create a virtual disk array:
    • In the Available Disks list, select a device (or disk image)
    • To add it to the Selected Disks list, click Add
    • Repeat steps a. and b. for every disk in the original array. If one of the disks is physically damaged and not accessible, and if you have selected RAID-0 or RAID-5 in step 2, from the Available Disks list add Damaged Device instead of the named damaged disk
    • To change the order of disks in the Selected Disks list, select a disk name and click Up or Down to change its position in the list
  4. To indicate the size of the stripe block, in the Options area, type the size of the block in kilobytes in the Stripe Block (RAID0 and RAID5) field. This is applicable only to RAID-0 and RAID-5 arrays. Standard values are 32Kb, 64Kb, 128Kb, 256Kb. If you are not sure, try each size until you get the correct one
  5. To indicate the offset and the size of the device, measured in sectors (each sector is 512 bytes), in the Disk Area to Use in RAID (Sectors) area, type the values in the Device offset and Size fields. In most cases, the default values are acceptable. Some RAID controllers use only part of the disk surface. For example HighPoint 370 uses the first 100 sectors on the first drive for its own system information. In this case you would specify the offset as 100 sectors
  6. Click OK to start Virtual Disk Array reassembly process
  7. In the Local System Devices list, a new Virtual Disk Array device node appears. You may treat this new node and its contents the same way that you treat other device nodes in the list.

You may follow the standard steps to scan the Virtual Disk Array node, then search for files and folders to be recovered. You may also create a Disk Image of the whole Virtual Disk Array to work with it later on.

You may consult your RAID controller manufacturer to determine the proper RAID5 type being used in hardware.

 

This document is available in PDF format,